Ipakita ang simpleng tala ng item

dc.contributor.adviserArmadillo, Rufel Zepth D.
dc.contributor.authorBiongan, Shan Michael B.
dc.contributor.authorDavila, Kyle Christian V.
dc.contributor.authorDayot, Patricia P.
dc.contributor.authorJamora, Sean Gabriel L.
dc.contributor.authorSoltis, Stroll S.
dc.coverage.spatialIloiloen_US
dc.date.accessioned2026-02-07T03:52:36Z
dc.date.available2026-02-07T03:52:36Z
dc.date.issued2025-04
dc.identifier.citationBiongan, S. M. B., Davila, K. C. V., Dayot, P. P., Jamora, S. G. L., & Soltis, S. S. (2025). Impact study on the additional air conditioning load at Central Philippine University [Unpublished bachelor's special paper]. Central Philippine University.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12852/3658
dc.descriptionAbstract onlyen_US
dc.description.abstractThis study examines how an added load on the electrical infrastructure of Central Philippine University (CPU) affects the system’s capability to carry increased energy requirements. The research targets the evaluation of existing transformer banks and energy consumption patterns to find if the current infrastructure is sufficient to support added cooling systems without causing power overloads or voltage instability. The data collection was done by measuring load, transformer capacity and energy consumption with a data logger and a systematic measurement technique. The baseline energy consumption of university buildings was also studied, energy requirements of new air conditioning units were estimated, and the total energy consumption was projected including the new load. The key findings indicate that the electrical system of the CPU may need improvement in the transformer capacity, power factor correction and load distribution for system reliability and efficiency. The results presented in this research can be used to help the university administration, facilities management, and future researchers find ways of developing sustainable energy solutions and infrastructure improvements in academic institutions.en_US
dc.format.extentviii, 144 leavesen_US
dc.language.isoen_USen_US
dc.publisherCentral Philippine Universityen_US
dc.subject.lccTK 165 .B56 2025en_US
dc.subject.lcshElectric power systems--Protectionen_US
dc.subject.lcshElectric power systems--Load dispatchingen_US
dc.subject.lcshElectric transformers--Testingen_US
dc.subject.lcshAir conditioning--Energy consumptionen_US
dc.subject.lcshCentral Philippine Universityen_US
dc.subject.lcshElectric power consumption--Measurementen_US
dc.subject.lcshElectric power factoren_US
dc.subject.lcshElectric power distributionen_US
dc.titleImpact study on the additional air conditioning load at Central Philippine Universityen_US
dc.typeSpecial paperen_US
dcterms.accessRightsLimited public accessen_US
dc.description.bibliographicalreferencesIncludes bibliographical referencesen_US
dc.contributor.committeememberJava, Alberto A.
dc.contributor.committeememberParreño, Marjee Rose
dc.contributor.committeememberIsidto, Jon Joven A.
dc.contributor.departmentCollege of Engineeringen_US
dc.description.degreeBachelor of Science in Electrical Engineeringen_US


Mga file sa item na ito

Thumbnail

Lumilitaw ang item na ito sa mga sumusunod na (mga) Koleksyon

Ipakita ang simpleng tala ng item