Impact study on the additional air conditioning load at Central Philippine University

Thumbnail
View/Open
COE_BSEE_BionganSM_2025_Ab.pdf (116.9Kb)
Downloads: 3
Request
Request a full text copy
Page views
45
发表日期
2025-04
作者
Biongan, Shan Michael B.
Davila, Kyle Christian V.
Dayot, Patricia P.
Jamora, Sean Gabriel L.
Soltis, Stroll S.
论文指导
Armadillo, Rufel Zepth D.
小组成员
Java, Alberto A.
Parreño, Marjee Rose
Isidto, Jon Joven A.
股票 
 
元數據
显示条目完整记录

摘要
This study examines how an added load on the electrical infrastructure of Central Philippine University (CPU) affects the system’s capability to carry increased energy requirements. The research targets the evaluation of existing transformer banks and energy consumption patterns to find if the current infrastructure is sufficient to support added cooling systems without causing power overloads or voltage instability. The data collection was done by measuring load, transformer capacity and energy consumption with a data logger and a systematic measurement technique. The baseline energy consumption of university buildings was also studied, energy requirements of new air conditioning units were estimated, and the total energy consumption was projected including the new load. The key findings indicate that the electrical system of the CPU may need improvement in the transformer capacity, power factor correction and load distribution for system reliability and efficiency. The results presented in this research can be used to help the university administration, facilities management, and future researchers find ways of developing sustainable energy solutions and infrastructure improvements in academic institutions.
描述
Abstract only
网址
https://hdl.handle.net/20.500.12852/3658
建议引文
Biongan, S. M. B., Davila, K. C. V., Dayot, P. P., Jamora, S. G. L., & Soltis, S. S. (2025). Impact study on the additional air conditioning load at Central Philippine University [Unpublished bachelor's special paper]. Central Philippine University.
文件类型
Special paper
主题
Electric power systems--Protection OCLC - FAST (Faceted Application of Subject Terminology); Electric power systems--Load dispatching OCLC - FAST (Faceted Application of Subject Terminology); Electric transformers--Testing OCLC - FAST (Faceted Application of Subject Terminology); Air conditioning--Energy consumption OCLC - FAST (Faceted Application of Subject Terminology); Central Philippine University OCLC - FAST (Faceted Application of Subject Terminology); Electric power consumption--Measurement OCLC - FAST (Faceted Application of Subject Terminology); Electric power factor OCLC - FAST (Faceted Application of Subject Terminology); Electric power distribution OCLC - FAST (Faceted Application of Subject Terminology)
关键字
Iloilo TGN
部
College of Engineering
学位
Bachelor of Science in Electrical Engineering
货架位置
TK 165 .B56 2025
物理描述
viii, 144 leaves
集合
  • Bachelor of Science in Electrical Engineering [17]

相關項目

顯示由標題,作者,創造者和主題相關的項目。

  • Thumbnail

    A proposed intervention to improve the power quality and system efficiency of Calinog substation feeder 2 

    Roquios, Jose Redmond Eric S. (2007)
    Rationale Iloilo II Electric Cooperative, Inc. (ILECO II) is an electric distribution utility which supply electric power to the central part of the Province of Iloilo. With the passage of the RA 9136 otherwise known as ...
  • Thumbnail

    Upgrading of Asian Alcohol Corporation 1.5 MVA power substation 4.160 KV main circuit protection for normal and continuous production 

    De La Cruz, Vic Harde V. (2007)
    The purpose of this study is to determine the needs and requirements for a best design for the upgrading of Asian Alcohol Corporation (AAC) 1.5 MVA power substation main circuit protection for a reliable and continuous ...
  • Thumbnail

    The effect of rewiring the electrical power distribution system on the output voltages and maintenance at Central Philippine University 

    Idemne, Vitini Edhard O. (2007)
    This study aimed to assess the effects of rewiring the Electrical Power Distribution System on output voltages and maintenance of electrical devices at CPU campus. Specifically it determined and compared the output voltages ...

联系我们 | Send Feedback | https://creativecommons.org/licenses/by/4.0/ Logo by HLL
Central Philippine University © 2026
Managed by 
Henry Luce III LibraryHenry Luce III Library
 

 

Links
BAHÁNDÌAN Repository GuideDisclaimerFAQsSubmit your workNews and Updates

浏览

全部BAHÁNDÌAN文献分类和数据库按发布日期作者标题关键词该集合按发布日期作者标题关键词

My Account

LoginRegister

Statistics

View Usage Statistics
CPU Henry Luce III Library

联系我们 | Send Feedback | https://creativecommons.org/licenses/by/4.0/ Logo by HLL
Central Philippine University © 2026
Managed by 
Henry Luce III LibraryHenry Luce III Library
 

 

EXTERNAL LINKS DISCLAIMER

This link is being provided as a convenience and for informational purposes only. Central Philippine University bears no responsibility for the accuracy, legality or content of the external site or for that of subsequent links. Contact the external site for answers to questions regarding its content.

If you come across any external links that don't work, we would be grateful if you could report them to the repository administrators.

Click DOWNLOAD to open/view the file. Chat Bertha to inform us in case the link we provided don't work.

Download