Design, construction and testing of a three-phase low voltage power supply
요약
This study aimed to design construct and test a Three-Phase Low Voltage Variable Power Supply for EE/ECE Laboratory with the following component: three-phase high voltage power supply of 220VAC, low voltage variable three-phase AC power supply with an output of 3V, 4.5V, 6V, 9V, 12V and DC output of ±12V, 15V, ±1.25V - ±12V All output except 220VAC are provided with over current circuit protection to protect the circuit and the component from overload and accidental short circuit, The power supply was tested and evaluated at the EF/ECF Laboratory (Electronics Lab), The parameters tested are the phase angle, (for .AC output voltage only), output voltage, and maximum load current for both DC and AC output. In testing the power supply, it requires source voltage of 220VAC and the actual testing, the supply voltage are 210.8V, 211.5V, and 211.3V tor phase 1, phase 2 and phase 3, respectively. This value is lower compared to the required voltage base on the design, yet this value are tolerable and can be used for testing and evaluation with a minimal amount of deviation from the expected value. The regulated DC power supply output voltage is within a tolerable limit regardless of the source voltage changes to the acceptable level from 200V to 240V.
The load current of 0.6A for AC and 0.7A for DC is more than enough for the required laboratory experiment, because the laboratory experiment was design not only for low current normally from 10mA - 500mA. The resulting phase angle arc close to 120 in degrees for each phase, shown in Table 5, this is only shows that the line are balance when we test the power supply. Take note that the phasing of the three phase low voltage power supply depend on the source voltage.
After testing the power supply, the result shows that all data have met the requirements with an acceptable amount or percent of error and therefore the design is valid, reliable and accurate and the designers can conclude that this power supply was satisfactorily made and very adoptable to the needs of the EE/ECE Laboratory.
기술
Abstract only
Full text available
Associated Content
Full paper published in PatubasRelated study published in Scientia et Fides
추천 인용
Alguinado, R. A., Jr. , Manajero, R. D. & Rubidy, R. S. (2006). Design, construction and testing of a three-phase low voltage power supply (Research report). Jaro, Iloilo City: University Research Center, Central Philippine University.
유형
Technical Report주제
선반 위치
GSL 621.3072 Al38
물리적 설명
iii, 45 leaves
Collections
- Research reports [167]