Level of harmonics produced by the variable frequency drive controller used in the induction type water pump motor of Central Philippine University

Thumbnail
Voir/Ouvrir
Research report abstract (462.0Ko)
Downloads: 38
Request
Request a full text copy
Page views
458
Date
2014-11
Auteur
Idemne, Vitini Edhard O.
Alguidano, Ramon A. Jr.
Java, Alberto A.
Armadillo, Ruben M.
Lagos, Gelvie C.
Nava, Babylou G.
Sacramento, Yeisel S.
Acanto, Caesar Rico S.
Share 
 
Metadata
Afficher la notice complète

Résumé
The determination of the level of harmonics produced by the variable frequency drive (VFD) controller used to control the induction-type water pump motor at the water pumping station of Central Philippine University (CPU) was focused specifically on the electrical noise or harmonic level generated by the controller in terms of its amplitude and frequency. The level of harmonic content was acceptable based on the IEEE Std 519- 1992 of no more than 5% with the use of the controller and its effects on electronics and electrical systems connected in the same pick off point. It was also determined whether the system would significantly improve motor performance. Lastly, it was determined whether the system would significantly reduce energy consumption. Based on the results of the tests, the harmonics of the supply voltage at no load was 2.25%. During the system operation where a five (5) Hp induction type motor load was controlled direct-on-line (DOL), the harmonics generated was about 2.10%. However, by using the controller, it was found out that there was an increase in the amplitude and the number of harmonics present in the system. The harmonics produced at the source terminal with controller was about 3.93 %, showing an increase of 1.83% compared to without the use of the controller. However, the increase is minimal because 3.93 % is within the acceptable limits of 5% for electronics circuits and systems. However, this is not acceptable for medical and other related highly sensitive instruments, which require a THD of not more than 3%. In contrast to this, the harmonics generated at the load terminal was about 8.42%, which was higher compared to the THD at the input terminal and was very much higher than the required allowable level. The controller produced a significant level of harmonics that could cause interference to nearby electronic appliances that are sensitive to electrical noise within very close proximity. Nevertheless, this noise or harmonic generated was not significantly induced at the source terminal. Furthermore, there was no reduction on the energy consumption with the use of the controller over the DOL control mode. In contrast, the use of the controller gave the following benefits: it eliminated the very high current surges and sudden high starting torque during the motor start up; balanced the motor supply between phases; and, caused an increase in the revolution-per minute (rpm) of the motor thereby improving the performance of the motor. The same controller could be put to good use with some of the other pump motors around the campus.
Description
Abstract only
Associated Content
Full paper published in Scientia et Fides
URI
https://hdl.handle.net/20.500.12852/825
Suggested Citation
Idemne, V. E. O. , Alguidano, R. A. , Jr., Java, A. A. , Armadillo, R. M. , Lagos, G. C. , Nava, B. G. , ... & Acanto, C. R. S. (2014). Level of harmonics produced by the variable frequency drive controller used in the induction type water pump motor of Central Philippine University (Research report). Jaro, Iloilo City: University Research Center, Central Philippine University.
Type
Technical Report
Sujet
Harmonics (Electric waves) OCLC - FAST (Faceted Application of Subject Terminology); Electric power systems OCLC - FAST (Faceted Application of Subject Terminology); Electric power OCLC - FAST (Faceted Application of Subject Terminology)
Keywords
Harmonics; Variable frequency drive controller; Water pump motor; Electrical supply
Shelf Location
GSL 620.0072 L576
Physical Description
ix, 38 leaves
Collections
  • Research reports [13]
  • Research reports [167]

Contactez-nous | Faire parvenir un commentaire | https://creativecommons.org/licenses/by/4.0/ Logo by HLL
Central Philippine University © 2025
Managed by 
Henry Luce III LibraryHenry Luce III Library
 

 

Links
BAHÁNDÌAN Repository GuideDisclaimerFAQsSubmit your workNews and Updates

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire

Statistiques

Statistiques d'usage de visualisation
CPU Henry Luce III Library

Contactez-nous | Faire parvenir un commentaire | https://creativecommons.org/licenses/by/4.0/ Logo by HLL
Central Philippine University © 2025
Managed by 
Henry Luce III LibraryHenry Luce III Library
 

 

EXTERNAL LINKS DISCLAIMER

This link is being provided as a convenience and for informational purposes only. Central Philippine University bears no responsibility for the accuracy, legality or content of the external site or for that of subsequent links. Contact the external site for answers to questions regarding its content.

If you come across any external links that don't work, we would be grateful if you could report them to the repository administrators.

Click DOWNLOAD to open/view the file. Chat Bertha to inform us in case the link we provided don't work.

Download