Rehabilitation, testing, and evaluation of the solar PV system of Filamer Christian University, Roxas City, Capiz

Thumbnail
Открыть
Special paper abstract (728.4Kb)
Downloads: 100
Page views
904
Дата
2013
Автор
Dador, Jomar A.
Thesis Adviser
Alguidano, Ramon A. Jr.
Defense Panel Chair
David, Fely P.
Defense Panel Member
Calibjo, Cirilo C.
Acanto, Caesar Rico S.
Share 
 
Metadata
Показать полную информацию

Аннотации
This study aimed to rehabilitate, test, and evaluate the solar PV system of Filamer Christian University (FCU), Roxas City, Capiz. The rehabilitation of the PV system is expected to provide numerous benefits to the university such as additional source of electric power, promotion of renewable energy to local society of Capiz, and it will also serve as a training module for the laboratory experiments of the Electronics Engineering department.

The solar PV system of FCU comprised of five building blocks: the PV modules; the batteries; the charge controller, inverter and the load. Specifically, the 14 80 Watt peak PV modules, 30 A 12/24 V charge controller, 1500 W pure sine-wave inverter and the 4 120 Ah batteries are used. The system is expected to light the President’s office located at the second floor of the Centennial building of FCU. The rehabilitation of the PV system was done based on the existing solar PV system of FCU and was transferred from the Technology Building to Centennial Building of the said university. The rehabilitation process included the installation of the PV panels, combining the output of the PV panels to the combiner junction box, connecting the combined output of the PV panels to the charge controllers, then to the batteries, and finally to the inverter. The components of the entire assembly was constructed and successfully implemented using locally available products with the best circuit options for functionality and reliability of the system which provides 1 kilowatt source of electricity.

The solar PV system of FCU was tested and evaluated based on the features and specification required and successfully gave reasonable results. The system successfully indicated the desired output data needed based on its nameplate rating using the input voltage and current from the PV modules and the batteries.
Описание
Abstract only
URI
https://hdl.handle.net/20.500.12852/956
Suggested Citation
Dador, J. A. (2013). Rehabilitation, testing, and evaluation of the solar PV system of Filamer Christian University, Roxas City, Capiz (Unpublished Master's special paper). Central Philippine University, Jaro, Iloilo City.
Type
Special paper
Тематика
Solar energy OCLC - FAST (Faceted Application of Subject Terminology); Photovoltaic power systems OCLC - FAST (Faceted Application of Subject Terminology); Photovoltaic power systems--Evaluation OCLC - FAST (Faceted Application of Subject Terminology); Photovoltaic power systems--Testing OCLC - FAST (Faceted Application of Subject Terminology); Photovoltaic power generation OCLC - FAST (Faceted Application of Subject Terminology); Philippines--Roxas OCLC - FAST (Faceted Application of Subject Terminology)
Keywords
Filamer Christian University (FCU); Roxas TGN
Department
College of Engineering
Degree
Master of Engineering
Shelf Location
GSL Theses 621.3872 D127
Physical Description
xi, 82 pages
Collections
  • Master of Engineering major in Electrical Engineering [32]

Контакты | Отправить отзыв | https://creativecommons.org/licenses/by/4.0/ Logo by HLL
Central Philippine University © 2025
Managed by 
Henry Luce III LibraryHenry Luce III Library
 

 

Links
BAHÁNDÌAN Repository GuideDisclaimerFAQsSubmit your workNews and Updates

Просмотр

Весь DSpaceСообщества и коллекцииДата публикацииАвторыНазванияТематикаЭта коллекцияДата публикацииАвторыНазванияТематика

Моя учетная запись

ВойтиРегистрация

Статистика

Просмотр статистики использования
CPU Henry Luce III Library

Контакты | Отправить отзыв | https://creativecommons.org/licenses/by/4.0/ Logo by HLL
Central Philippine University © 2025
Managed by 
Henry Luce III LibraryHenry Luce III Library
 

 

EXTERNAL LINKS DISCLAIMER

This link is being provided as a convenience and for informational purposes only. Central Philippine University bears no responsibility for the accuracy, legality or content of the external site or for that of subsequent links. Contact the external site for answers to questions regarding its content.

If you come across any external links that don't work, we would be grateful if you could report them to the repository administrators.

Click DOWNLOAD to open/view the file. Chat Bertha to inform us in case the link we provided don't work.

Download