Recherche
Voici les éléments 1-5 de 5
Proposed engineering computer laboratory expansion of Central Philippine University
(2001)
The Proposed Engineering Computer Laboratory Expansion of the Central Philippine University will cover the civil, electrical, and network rehabilitation. The project will allow to increase the number of computers inside ...
Analog and digital trainer for EE/ECE laboratory
(2003)
The analog and digital trainer is one of the basic requirements for electronics laboratory. This equipment is used when performing the laboratory experiment in electronics and some laboratory experiment in electrical ...
Status and condition of computer facilities, hardware and software at WVSU Pototan Campus: A basis for designing an intervention proposal
(2007)
This study aims to assess the status and condition of computer facilities, hardware, and software at WVSU-Pototan Campus in order to have a basis for an intervention proposal.
Lack of computer facilities, poor computer: ...
Energy audit of the five computer laboratories of St. Anthony’s College: Lighting system, air-conditioning system, electrical system and equipment
(2017)
St. Anthony’s College (SAC) is a Catholic, private institution of higher learning which offers different courses using computer laboratory facilities. The laboratories are mainly equipped with computers, air-conditioners and lights and these consume a large amount of energy during laboratory hours. To reduce energy consumption and enhance the efficiency of the laboratories, the study entitled Energy Audit of the Five Computer Laboratories of St. Anthony’s College: Lighting System, Air-Conditioning System and Electrical System and Equipment was conducted. This study was only limited to the five computer laboratories of SAC and its main objective is to audit the air-conditioners, lights and computers. The data were gathered by using the data logger for the electrical parameters; anemometer and temperature humidity meter was used to check the performance of the three major parts of an air-conditioner and lux meter was used to check the luminance level of lights. The data were analyzed to determine the efficiency of the air-conditioners, lights and computers to calculate the Annual Energy and Monetary Losses. The annual energy loss for the lighting, air-conditioning and computer is 25,742.00 kW-hr. While the annual monetary loss for air-conditioning is Php 218,740.83; for the lights Php 7,036.21 and for the computers Php 31,642.96. Thus, the total monetary loss of the lights, air-conditioners and computers is Php 257,420.00 which is computed at Php 10.00 kW-hr in 200 days. This loss could be turned into savings if the policies, standard, procedure and guidelines will be implemented in the laboratory that could enhance the efficiency of the equipment....
Proposed computer center for the College of Engineering, Central Philippine University
(2001)
The laboratory of the College of Engineering at present cannot provide enough space and equipment required by the courses using it. It can only accommodate, at one time, 50 students. With the present enrollment figures, ...