Search
Now showing items 11-20 of 25
Design and development of electronics workbench (CPUBENCH) for EE/ECE laboratory
(Central Philippine University, 2011-12)
The Electronic workbench (CPUBENCH) for EE/ECE Laboratory was designed based on the basic requirements for the electronics laboratory. This workbench is used when performing the laboratory experiments in electronics, basic ...
Proposed solution to address traffic congestion at EL 98 - Benigno Aquino Avenue intersection
(2014)
Today, there are more than one billion cars on the road worldwide and that number will double by 2020, and when the number of vehicles reaches the capacity of the road, particularly at intersections, traffic congestion ...
VCO physicochemical properties of various coconut ages: Basis for optimization of raw material input of VCO production
(2017)
This experimental study aimed to produce, measure and analyze the physicochemical properties of Ariana VCO using the Fresh Wet Method (Cold Process) in relation to coconut maturity using Association of Analytical Communities ...
The design and construction of a wastewater purification system for the main campus of Capiz State University (a pilot scale)
(2012-04)
This study was conducted to design and construct a water purifying system that will treat the wastewater produced by the CapSU main campus. Wastewater produced by CapSU was evaluated and the results suggested the need for ...
Energy audit of the five computer laboratories of St. Anthony’s College: Lighting system, air-conditioning system, electrical system and equipment
(2017)
St. Anthony’s College (SAC) is a Catholic, private institution of higher learning which offers different courses using computer laboratory facilities. The laboratories are mainly equipped with computers, air-conditioners and lights and these consume a large amount of energy during laboratory hours. To reduce energy consumption and enhance the efficiency of the laboratories, the study entitled Energy Audit of the Five Computer Laboratories of St. Anthony’s College: Lighting System, Air-Conditioning System and Electrical System and Equipment was conducted. This study was only limited to the five computer laboratories of SAC and its main objective is to audit the air-conditioners, lights and computers. The data were gathered by using the data logger for the electrical parameters; anemometer and temperature humidity meter was used to check the performance of the three major parts of an air-conditioner and lux meter was used to check the luminance level of lights. The data were analyzed to determine the efficiency of the air-conditioners, lights and computers to calculate the Annual Energy and Monetary Losses. The annual energy loss for the lighting, air-conditioning and computer is 25,742.00 kW-hr. While the annual monetary loss for air-conditioning is Php 218,740.83; for the lights Php 7,036.21 and for the computers Php 31,642.96. Thus, the total monetary loss of the lights, air-conditioners and computers is Php 257,420.00 which is computed at Php 10.00 kW-hr in 200 days. This loss could be turned into savings if the policies, standard, procedure and guidelines will be implemented in the laboratory that could enhance the efficiency of the equipment....
Design, construction and testing of a low cost mini electric steam generator
(Central Philippine University, 2010-02)
This study aimed to design, construct and test a Low Cost Mini Electric Steam Generator for Physics Laboratory with the following components: the AC power supply, heater, boiler, water pump, water level controller, temperature ...
Design of drinking water treatment facility system in Central Philippine University
(Central Philippine University, 2016-12)
This project study presents an innovative way of constructing a drinking water treatment facility system within Central Philippine University. It starts with the preparation of a preliminary process flow that can treat raw ...
Level of harmonics produced by the variable frequency drive controller used in the induction type water pump motor of Central Philippine University
(2014-11)
The determination of the level of harmonics produced by the variable frequency drive (VFD) controller used to control the induction-type water pump motor at the water pumping station of Central Philippine University (CPU) ...
Proposed parking facilities for the local heritage site of Iloilo City
(Asian Transportation Research Society, 2012)
Iloilo City is one of the Philippines’ premiere cities. The city has 8,407 business establishments of which 1,182 were recently established. Every year, there is an estimated 11% of increase in the number of business ...
Introduction of bus and BRT systems along a major road corridor in Iloilo City, Philippines
(Transportation Science Society of the Philippines, 2014)
Over the years, urban travel demand in Philippines has increased tremendously amounting to the need of high capacity public transport as an urban mobility. Primarily, urban population growth, migration from rural areas, ...