Show simple item record

dc.contributor.adviserLagos, Gelvie C.
dc.contributor.authorSilvederio, Julienne Marie B.
dc.contributor.authorSultan, Mycka Murielh B.
dc.contributor.authorTabiolo, Franz J.
dc.contributor.authorCabig, Denver C.
dc.date.accessioned2024-05-10T06:49:38Z
dc.date.available2024-05-10T06:49:38Z
dc.date.issued2020-03
dc.identifier.citationSilvederio, J. M. B., Sultan, M. M. S., Tabiolo, F. J., & Cabig, D. C. (2020). Study of the levels of harmonics in Central Philippine University [Unpublished special paper]. Central Philippine University.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12852/3007
dc.descriptionAbstract onlyen_US
dc.description.abstractThis study was conducted to determine the levels of harmonics in Central Philippine University. Harmonic content and power factor data of the 12 transformer banks in the university were gathered using Fluke 1735-three phase power logger Survey of the connected loads and defective electrical and electronic devices in all the buildings and functional areas of the university was conducted The type of device were correlated with the harmonic order with the aid of Pearson Correlation Analysis. After the data analysis of the THDV and TDD content of each transformer bank, it was found out that the levels of harmonics in CPU electrical system are all in the acceptable range based on the IEEE Std-519. It has been found out that switched-mode power supply devices and ACU/Refrigerator have no linear relationship with the harmonic orders 3rd, 5th, and 7th. Variable Speed drives have moderate negative linear relationship with 7th harmonic content in line C. Lighting devices have moderate positive linear relationship with 7th harmonic content in line B. Heating devices have moderate negative linear relationship with 3rd harmonic content in line B and strong negative linear relationship with 7th harmonic content in line B. The levels of harmonics were not considered as the main contributors of the recorded defective devices. With the gathered and analyzed data, it has been concluded that the buildings in Central Philippine University are not susceptible to the impacts of harmonics. The gathered power factor and TDD per line in each bank have shown no significant linear relationship.en_US
dc.format.extent509 leaves : ill. (col.).en_US
dc.language.isoen_USen_US
dc.publisherCentral Philippine Universityen_US
dc.subject.lccTK 165 S55 2020en_US
dc.subject.lcshHarmonics (Electric waves)en_US
dc.subject.lcshCentral Philippine Universityen_US
dc.subject.lcshElectric power system stabilityen_US
dc.subject.lcshElectric power-plants--Loaden_US
dc.titleStudy of the levels of harmonics in Central Philippine Universityen_US
dc.typeSpecial paperen_US
dcterms.accessRightsLimited public accessen_US
dc.contributor.chairJava, Alberto A.
dc.contributor.chairAcanto, Caesar Rico S.
dc.contributor.chairIdemne, Vitini Edhard O.
dc.contributor.departmentCollege of Engineeringen_US
dc.description.degreeBachelor of Science in Electrical Engineeringen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record