dc.contributor.authorIdemne, Vitini Edhard O.
dc.contributor.authorAlguidano, Ramon A. Jr.
dc.contributor.authorJava, Alberto A.
dc.contributor.authorArmadillo, Ruben M.
dc.contributor.authorLagos, Gelvie C.
dc.contributor.authorNava, Babylou G.
dc.contributor.authorSacramento, Yeisel S.
dc.contributor.authorAcanto, Caesar Rico S.
dc.date.accessioned2020-12-29T02:44:22Z
dc.date.available2020-12-29T02:44:22Z
dc.date.issued2018-09-01
dc.identifier.citationIdemne, V. E. O., Alguidano, R. A., Java, A. A., Armadillo, R. M., Lagos, G. C., Nava, B. G., Sacramento, Y. S., & Acanto, C. R. S. (2018). Level of harmonics produced by variable frequency drive controller used in induction type water pump motor. Scientia et Fides, 1(1), 34-46.en_US
dc.identifier.issn2546-1338
dc.identifier.urihttps://hdl.handle.net/20.500.12852/21
dc.description.abstractThis study focuses specifically on the determination of electrical noise or harmonic level generated by the variable frequency drive controller in terms of its amplitude and frequency. The central area of concern is the effect of harmonics on the power quality of the electrical supply of Central Philippine University at the point of the pump-motor equipment. Based on the results of the tests, the harmonics of the supply voltage was 2.25%. Running the 5-HP motor directly produced a lower harmonics of 2.10%. When the controller was used to run the motor, the controller in itself produced a significant level of harmonics of 8.42%which interferes with nearby electronic appliances within a very close proximity. A substantial part of the harmonics produced by the controller is filtered from going out of the device itself, so that the harmonic level at the source terminal was about 3.93 %, showing an increase of 1.83% compared to running the motor without the use of the controller. The value is within the acceptable limits of 5% for electronic circuits and systems, but not acceptable for medical and other related highly sensitive instruments, which require a total harmonic distortion (THD) of not more than 3%.en_US
dc.language.isoenen_US
dc.publisherCentral Philippine Universityen_US
dc.subject.lcshElectric power systemsen_US
dc.subject.lcshElectric poweren_US
dc.subject.lcshHarmonics (Electric waves)en
dc.titleLevel of harmonics produced by variable frequency drive controller used in induction type water pump motoren_US
dc.typeArticleen_US
dc.citation.firstpage34en_US
dc.citation.lastpage46en_US
dc.citation.journaltitleScientia et Fidesen_US
dc.citation.volume1en_US
dc.citation.issue1en_US
local.subjectHarmonicsen_US
local.subjectVariable frequency drive controlleren_US
local.subjectWater pump motoren_US
local.subjectElectrical supplyen_US