Показать сокращенную информацию

dc.contributor.adviserAlguidano, Ramon A. Jr.
dc.contributor.authorNietes, Ailene F.
dc.date.accessioned2021-08-02T00:32:36Z
dc.date.available2021-08-02T00:32:36Z
dc.date.issued2017
dc.identifier.citationNietes, A. F. (2017). Energy audit of the five computer laboratories of St. Anthony’s College: Lighting system, air-conditioning system, electrical system and equipment (Unpublished Master’s special paper). Central Philippine University, Jaro, Iloilo City.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12852/1270
dc.descriptionAbstract onlyen_US
dc.description.abstractSt. Anthony’s College (SAC) is a Catholic, private institution of higher learning which offers different courses using computer laboratory facilities. The laboratories are mainly equipped with computers, air-conditioners and lights and these consume a large amount of energy during laboratory hours. To reduce energy consumption and enhance the efficiency of the laboratories, the study entitled Energy Audit of the Five Computer Laboratories of St. Anthony’s College: Lighting System, Air-Conditioning System and Electrical System and Equipment was conducted. This study was only limited to the five computer laboratories of SAC and its main objective is to audit the air-conditioners, lights and computers. The data were gathered by using the data logger for the electrical parameters; anemometer and temperature humidity meter was used to check the performance of the three major parts of an air-conditioner and lux meter was used to check the luminance level of lights. The data were analyzed to determine the efficiency of the air-conditioners, lights and computers to calculate the Annual Energy and Monetary Losses. The annual energy loss for the lighting, air-conditioning and computer is 25,742.00 kW-hr. While the annual monetary loss for air-conditioning is Php 218,740.83; for the lights Php 7,036.21 and for the computers Php 31,642.96. Thus, the total monetary loss of the lights, air-conditioners and computers is Php 257,420.00 which is computed at Php 10.00 kW-hr in 200 days. This loss could be turned into savings if the policies, standard, procedure and guidelines will be implemented in the laboratory that could enhance the efficiency of the equipment.en_US
dc.format.extentix, 87 leavesen_US
dc.language.isoenen_US
dc.subject.ddcGSL Theses 620.0072 N558en_US
dc.subject.lcshComputation laboratoriesen_US
dc.subject.lcshComputation laboratories--Equipment and suppliesen_US
dc.subject.lcshElectric utilitiesen_US
dc.subject.lcshAir conditioningen_US
dc.subject.lcshEnergy consumptionen_US
dc.subject.lcshComputation laboratories--Energy consumptionen_US
dc.subject.lcshEnergy auditingen_US
dc.subject.lcshElectric lightingen_US
dc.titleEnergy audit of the five computer laboratories of St. Anthony’s College: Lighting system, air-conditioning system, electrical system and equipmenten_US
dc.title.alternativeEnergy audit of the five computer laboratories of St. Anthony’s College: lighting system, air-conditioning system, and electrical system and equipmenten_US
dc.typeSpecial paperen_US
dc.description.bibliographicalreferencesIncludes bibliographical referencesen_US
dc.contributor.committeememberMolina, Dany C.
dc.contributor.committeememberSacramento, Yeseil S.
dc.contributor.committeememberJava, Alberto A.
dc.contributor.committeememberAcanto, Caesar Rico S.
dc.contributor.departmentSchool of Graduate Studiesen_US
dc.description.degreeMaster of Engineering (major in Electrical Engineering)en_US
local.subjectSt. Anthony’s College (SAC)en_US


Файлы в этом документе

Thumbnail

Данный элемент включен в следующие коллекции

Показать сокращенную информацию