Proposed solution to address traffic congestion at EL 98 - Benigno Aquino Avenue intersection
(2014)
Today, there are more than one billion cars on the road worldwide and that number will double by 2020, and when the number of vehicles reaches the capacity of the road, particularly at intersections, traffic congestion ...
VCO physicochemical properties of various coconut ages: Basis for optimization of raw material input of VCO production
(2017)
This experimental study aimed to produce, measure and analyze the physicochemical properties of Ariana VCO using the Fresh Wet Method (Cold Process) in relation to coconut maturity using Association of Analytical Communities ...
The design and construction of a wastewater purification system for the main campus of Capiz State University (a pilot scale)
(2012-04)
This study was conducted to design and construct a water purifying system that will treat the wastewater produced by the CapSU main campus. Wastewater produced by CapSU was evaluated and the results suggested the need for ...
Energy audit of the five computer laboratories of St. Anthony’s College: Lighting system, air-conditioning system, electrical system and equipment
(2017)
St. Anthony’s College (SAC) is a Catholic, private institution of higher learning which offers different courses using computer laboratory facilities. The laboratories are mainly equipped with computers, air-conditioners and lights and these consume a large amount of energy during laboratory hours. To reduce energy consumption and enhance the efficiency of the laboratories, the study entitled Energy Audit of the Five Computer Laboratories of St. Anthony’s College: Lighting System, Air-Conditioning System and Electrical System and Equipment was conducted. This study was only limited to the five computer laboratories of SAC and its main objective is to audit the air-conditioners, lights and computers. The data were gathered by using the data logger for the electrical parameters; anemometer and temperature humidity meter was used to check the performance of the three major parts of an air-conditioner and lux meter was used to check the luminance level of lights. The data were analyzed to determine the efficiency of the air-conditioners, lights and computers to calculate the Annual Energy and Monetary Losses. The annual energy loss for the lighting, air-conditioning and computer is 25,742.00 kW-hr. While the annual monetary loss for air-conditioning is Php 218,740.83; for the lights Php 7,036.21 and for the computers Php 31,642.96. Thus, the total monetary loss of the lights, air-conditioners and computers is Php 257,420.00 which is computed at Php 10.00 kW-hr in 200 days. This loss could be turned into savings if the policies, standard, procedure and guidelines will be implemented in the laboratory that could enhance the efficiency of the equipment....
Performance evaluation of concrete produced using recycled concrete as both fine and coarse aggregates
(2010)
Infrastructure is at the top of list of factors that influence competitiveness due to rapid economic development in cities and has developed concrete into the most significant construction material in the world. This is ...